Freezer dryer selection guide
Inlet air temperature and pressure correction coefficientC1
Inlet pressure (8kgf/cm2) |
Inlet temperature | |||||
25℃ | 30℃ | 35℃ | 40℃ | 45℃ | 50℃ | |
3 | 1.42 | 1.00 | 0.79 | 0.63 | 0.51 | 0.43 |
4 | 1.50 | 1.08 | 0.87 | 0.72 | 0.60 | 0.52 |
5 | 1.57 | 1.13 | 0.92 | 0.77 | 0.65 | 0.56 |
6 | 1.63 | 1.18 | 0.96 | 0.81 | 0.68 | 0.60 |
7 | 1.67 | 1.22 | 1.00 | 0.84 | 0.71 | 0.63 |
8 | 1.72 | 1.25 | 1.03 | 0.87 | 0.74 | 0.65 |
9 | 1.76 | 1.29 | 1.07 | 0.91 | 0.78 | 0.67 |
10 | 1.81 | 1.33 | 1.10 | 0.93 | 0.80 | 0.70 |
11 | 1.84 | 1.36 | 1.13 | 0.96 | 0.82 | 0.73 |
12 | 1.87 | 1.38 | 1.16 | 0.98 | 0.84 | 0.75 |
13 | 1.90 | 1.41 | 1.18 | 1.00 | 0.86 | 0.77 |
14 | 1.93 | 1.44 | 1.21 | 1.02 | 0.88 | 0.80 |
Environment cooling water temperature correction coefficientC2
Environment cooling water temperature | 25℃ | 30℃ | 32℃ | 35℃ | 40℃ | 45℃ |
Coefficient | 1.08 | 1.02 | 1.00 | 0.97 | 0.92 | 0.87 |
Dew point temperature correction coefficient C3
Dew point temperature | 2℃ | 3℃ | 5℃ | 7℃ | 10℃ |
Coefficient | 1 | 1.1 | 1.15 | 1.25 | 1.3 |
QS=QS×C1×C2×C3
QS is actual flow of freezing dryer, QS is rated flow of freezing dryer.
Previous: GL freezing compressed air dryer-Water cooling high temperature type
Next: GL heatless regeneration adsorption drier